Write a Review

2021 International Mechanical Code - Soft Cover

ITEM #: 3300S21

Prescriptive and performance-related provisions are used to establish minimum regulations for mechanical systems. The IMC was created using broad-based principles that allow for the use of new materials, methods, and designs. The following are significant changes in the 2021 IMC:

  • Clothes dryer exhaust terminals are required to be at least 3 ft. from any opening into a building.
  • Polyurethane spray-applied foam on the exterior of ducts in attics and crawl spaces required to meet specific smoke and flame index limits.
  • Fire and smoke dampers must be provided with approved access for inspection and maintenance.
  • Refrigerant tables updated to include new refrigerants.
  • Addition of condensate termination identification markings and discharge restrictions.
  • Approved factory-built combination intake/exhaust terminations permitted, relaxing separation requirement.
  • 30% reduction in minimum mechanical ventilation for whole-house balanced ventilation systems.
  • Continuous operation requirement for manicure and pedicure station exhaust systems.
  • Grease duct horizontal cleanout required within 3 ft. of a horizontal discharge fan.
More Details
$115.90
Adding to cart… The item has been added
MFR#: 3300S21

UPC:

Prescriptive and performance-related provisions are used to establish minimum regulations for mechanical systems. The IMC was created using broad-based principles that allow for the use of new materials, methods, and designs. The following are significant changes in the 2021 IMC:

  • Clothes dryer exhaust terminals are required to be at least 3 ft. from any opening into a building.
  • Polyurethane spray-applied foam on the exterior of ducts in attics and crawl spaces required to meet specific smoke and flame index limits.
  • Fire and smoke dampers must be provided with approved access for inspection and maintenance.
  • Refrigerant tables updated to include new refrigerants.
  • Addition of condensate termination identification markings and discharge restrictions.
  • Approved factory-built combination intake/exhaust terminations permitted, relaxing separation requirement.
  • 30% reduction in minimum mechanical ventilation for whole-house balanced ventilation systems.
  • Continuous operation requirement for manicure and pedicure station exhaust systems.
  • Grease duct horizontal cleanout required within 3 ft. of a horizontal discharge fan.
details

Prescriptive and performance-related provisions are used to establish minimum regulations for mechanical systems. The IMC was created using broad-based principles that allow for the use of new materials, methods, and designs. The following are significant changes in the 2021 IMC:

  • Clothes dryer exhaust terminals are required to be at least 3 ft. from any opening into a building.
  • Polyurethane spray-applied foam on the exterior of ducts in attics and crawl spaces required to meet specific smoke and flame index limits.
  • Fire and smoke dampers must be provided with approved access for inspection and maintenance.
  • Refrigerant tables updated to include new refrigerants.
  • Addition of condensate termination identification markings and discharge restrictions.
  • Approved factory-built combination intake/exhaust terminations permitted, relaxing separation requirement.
  • 30% reduction in minimum mechanical ventilation for whole-house balanced ventilation systems.
  • Continuous operation requirement for manicure and pedicure station exhaust systems.
  • Grease duct horizontal cleanout required within 3 ft. of a horizontal discharge fan.


2021 International Mechanical Code - Soft Cover      

$115.90
Adding to cart… The item has been added
SUGGESTED PRODUCTS